Description
1PC AK2515 VFD Audio Spectrum 15 Level Indicator VU Meter Screen For AmplifierProduct Description:
Dedicated VFD spectrum display, Resolution 25 X 15.
Support 32
HZ-16KHZ frequency sweep , Ensure the accuracy of each band.
The falling speed of the light bar, the holding time and the falling speed of the
peak can be adjusted separately.
Real output and smooth output I/ smooth output II selection
Clock brightness can be adjusted 3 levels.
Extended function interface(Infrared, sound source selection,
volume motor control, volume key, volume display, standby control)
Accurate clock display function (This function is entered after 10 seconds
without signal input and key operation).
(SD2405AL built-in crystal oscillator, the chip can ensure that the clock
accuracy
is + 5ppm (at 25 + 1 degrees Celsius), the annual error is less than 2.5 minutes)
Software AGC + custom output curve, In order to ensure that the input
signal in a large range of output effect is ideal.
Custom frequency band display to ensure that even the 25 segment,
can fully display the audio frequency range.
Specific operation:
Normal mode:
1. Single click
UP - Mode change
DOWN - Mode change
OK - Bottom line display or no in spectrum mode
2. Double-click
OK - Switching real / smooth I/ smooth II output
3. Three-click
OK - Menu effect switch, right -left transition / up - down transition / mid folding open
4. Four-click
OK - Volume display function on or off
5. Five-click
OK - Switch the extended port
output level, high or low level
6. Composite key
UP+DOWN -2 Seconds
A.(In the spectrum mode)
The external ports are switched on or off (including infrared interface,
a
udio source selection interface, volume motor control interface,
v
olume key interface, standby control interface).
B.(In the clock mode )
Switch the clock display effect.
UP+DOWN+OK -2 Seconds,
Enter the screen self-test program, press the OK button 1 second to exit.
UP+DOWN+OK -5 Seconds,
Enter infrared learning function, press OK button to exit in 1 second
UP+DOWN+OK -10 Seconds,
I
nfrared code recovery factory settings (the default is Tmall infrared remote control).
Important notes:
1. Because of the working conditions of VFD, there is a DC high voltage of about 38V,
so don't touch the VFD pins when it is working.
2. Because of the characteristics of VFD, long working brightness will be attenuated,
so it will become uneven, is a normal phenom
enon.
3. Because the clock module is selected parts, if there is no clock module installed,
then the relevant clock function instructions are invalid.
4. When there is no clock function, no signal input and button operation,
will enter standby state and display standby characters, in the external port closed setting ,
after 1 minutes it will close the filament power supply and VFD high voltage.